BIOGAS ANALYZER
GFM 406
Biogas portable gas analyser
â–ªEx. Rating: Ex II 2 G Ex ibIIB T1 Gb
â–ªMultichannel gas analyzer
â–ªMeasure up to 7 gases
â–ªUsing optical infra-red analyzer, electrochemical cells, and balance calculation
â–ªChoice of vane anemometer to measure the gas velocity of 0.5 –40m/s
â–ªOptional expansions to measure atmospheric, static and differential pressures
â–ªSiteManPC software include
GFM 426
Landfill gas extraction monitor
â–ªEx. Rating: Ex II 2 G Ex ibIIB T1 Gb
â–ªProvides measurements of up to 6 gases
â–ªUsing optical infra-red analyzer, electrochemical cells, and balance calculation
â–ªCalculated flow rate reading through differential pressure
â–ªOptional extras to measure velocity and temperature â–ª Built-in sample pump
â–ªProvides pressure measurements: Atmospheric; Static (Gauge); Differential.
â–ªSiteManPC software included
GFM 436
Site investigation, landfill and compliance
â–ªEx. Rating: Ex II 2 G Ex ibIIB T1 Gb
â–ªMeasure up to 6 gases
â–ª4 Wavelength optical infra-red analyzer
â–ªStorage of 2 water level readings from DIP meter taken at each borehole
â–ªOptional extras to measure velocity and temperature â–ªCapacity to measure gas pressure (differential and static) and flow rate (instantaneous and peak)
â–ªSiteManPC software included
GFM 610
Gas flow and pressure analyzer
â–ªEx. Rating: Ex II 2 G Ex ibIIB T1 Gb
â–ªMeasures flow rate, atmospheric and differential
â–ªVelocity and temperature measurements are available â–ªOptional vane anemometer available to measure the velocity of the gas
â–ªSiteManPC software included
GFM 226
Hidden Stowaway Detector
â–ªIP65 rated –ensuring the unit is dust tight and protected against water
â–ª User-friendly –designed to be used by anyone using or in the presence of CO2 gas. The interface makes it incredibly user-friendly.
â–ª-10 to 40 degrees C operating temperature
â–ªSiteManPC software included
â–ªAvailable sensor accessories:
-Straight needle probe
-Under door probe
-1m lance probe
Gazoscan
Remote Methane Detector
â–ªEx. Rating: II 2 G Ex ibis IIA T3 Gb
â–ªTunablediode laser absorption spectroscopy (TDLAS)
â–ªFast response (0.1 sec)
â–ªEasily detects at over 330 ft (~100m)
â–ªVisual and Audio Alarms
â–ªAdjustable settings
â–ªDetects through glass
â–ªBluetooth communication for data transmission
â–ªConnects with GAZOSURVEY mobile APP
-GPS Leak localization and survey traceability
-Note entry, email, picture capture, and storage
Click! Light
Limited-option model for cost-effective gas analysis. It can feature up to 5 gases (with 1 gas a balance calculation), 2 sample points, and a single data output option. The Click! Light can be installed up to 10m away from the sampling points.
Click! Ex
The Ex-model can measure up to 4 different gases from a single sample point, logging data to an internal SD card. An external control panel can also be housed outside of a zoned area for greater control of the analyser.
Click! Flexi
Accommodates all features of the Click! range. Our most popular model, the Flexi can incorporate several output options, up to 9 sample points, and accommodate external inputs via 4-20mA signals. The Flexi runs a sample-and-purge sequence to remove sampled gas from the sensors and the line, increasing sensor longevity and ensuring no residual gas is left behind that could distort the sample. Sample points can be up to 100m away from the analyzer.
Click! Safety +
Safety-enhanced model for use on industrial sites. The Safety + is a dual-enclosure design, separating potential ignition sources from the gas analysis modules. This model measures up to 5 gases with up to 4 sampling points, outputting data via 4-20mA signals and through the Gas Data portal.
InspectraMAX
Gas Leak Detecto
â–ªEx. Rating: II 2 G Ex ibop is IIB T3 Gb
â–ªTunablediode laser absorption spectroscopy (TDLAS)
â–ª0.5ppm methane sensitivity
â–ªTwo sampling speeds: 35 I/hour and 70 I/hour â–ªMeasurement range extending from 0ppm to 100% volume gas
â–ªVisual and Audio Alarms
â–ªConnects to the GAZOSURVEY mobile App (optional). â–ªGas leak detection traceability is guaranteed